ONLINE Multiple Choice Questions EE- Synchronous Generator PAR 7

91. In
order to reduce the harmonics in the emf generated in an alternator
(A) slots are skewed
(B) salient pole tips are chamfered
(C) winding is well distributed
(D) all of the above.

Get Answer

92. The
maximum power in a synchronous machine is obtained when the load angle is
(A)

(B) 85°
(C) 120°
(D)
135°.

Get Answer

93. The
emf generated due to nth harmonic component of flux in an alternator will be
(A) n times the fundamental emf
(B) same as fundamental emf
(C) less than the value of fundamental emf.

Get Answer

94. Synchronizing
torque comes into operation under all of the following cases EXCEPT
(A) phase difference between two voltages
(B) frequency difference between two voltages
(C) voltage difference between two voltages
(D) reduction in exciting current in one of
the alternators.

Get Answer

95. Unbalanced
3-phase stator currents cause
(A) double frequency currents in the rotor
(B) healing of rotor
(C) vibrations
(D) all of the above.

Get Answer

96. In
large generators protection provided against external faults is
(A) biased differential protection
(B) sensitive earth fault protection
(C) inter-turn fault protection
(D) all of the above.

Get Answer

97. Pitch factor is the ratio of the emfs of
(A) short pitch coil to full pitch coil
(B) full pitch winding to concentrated winding
(C)
full pitch winding to short pitch winding
(D) distributed winding to full pitch winding.

Get Answer

98.
In an alternator if the
winding is short pitched by 50 electrical degrees, its pitch factor will be
(A)
1.0
(B) 0.866
(C)
0.75
(D) 0.50.

Get Answer

99. The Potier’s triangle
separates
(A) stator losses and rotor losses
(B) fixed losses and variable losses
(C) armature voltage and field voltage
(D) armature leakage reactance and armature reaction mmf.

Get Answer

100. If a single phase alternator has 8 slots per pole uniformly
speed, but the winding is arranged with the middle two left empty, the breadth
coefficient will be
(A)
0.99
(B) 0.88
(C) 0.67
(D) 0.53.

Get Answer

101. Two alternators are running in parallel. If the field of one of
the alternator is adjusted, it will
(A) reduce its speed
(B) change its load
(C) change its power factor
(D) change its frequency.

Get Answer

102. A generator is operating by itself supplying the system loads.
The reactive power supplied by the generator will
(A)
depend on prime mover rpm
(B)
depend on type of
insulation used
(C) depend on the amount demanded by the load
(D)
depend on inter-coil
inductance.

Get Answer

103. Which of the following part plays important role in over speed
protection of a generator ?
(A)
Over current relay
(B) Alarm
(C)
Differential protection
(D) Governor.

Get Answer

104. Which type of protection is provided on a generator to protect
against stator insulation failure ?
(A) Differential protection
(B) Thermocouple actuated alarm
(C) Over current relay
(D) Reverse power relay.

Get Answer

105. Which relays comes into operation in the event of the failure of
prime mover connected to ihe generator ?
(A) Reverse power relay
(B) Differential relay
(C) Buchholz relay
(D) None of the above.

Get Answer